Portuguese Ministry of
Economy
National Institute of Engineering and Industrial
Technology
Industrial Microbiologic Laboratory
Report (ref. 566/01)
THE EFFICIENCY OF AN AIR STERILIZER MANUFACTURED
UNDER U.S. PATENT 5874050 IN REDUCING THE AIRBORNE
MICROBIAL LEVEL IN PARTIAL CLOSED ROOM AT D. ESTEFANIA
HOSPITAL, LISBON
OBJECTIVES
The main objective of this report is to verify the
efficiency of an air sterilizer model in reducing
airborne bacteria and fungus levels in partially closed
areas. This report verified the airborne microbial
levels in one admission room at the D. Estefania
Hospital during a 57 days period when the air sterilizer
manufactured under license of US Patent 5874050 was
plugged in.
METHODOLOGY
The chosen room for the test was one admission room
(beds 7,8,9 and 10) of the Obstetric Department.
Initially during 35 days just one device was placed.
Device was plugged in on August 6, 2001 after collecting
that day air samples |